Index News Seller Buyer Product Company

4/8/16 zones fire alarm panel

  • Date Listed:2018-12-26 15:03:30
    Country:China>Guangdong>shenzhen
    4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China
    Company:Shenzhen Zoanco Electronics Co.,Ltd.
    Mobile:15220176087
    Tell:86-755-23015236

    The PANEL is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level. Product Features 4,8,16 Class B Initiating Device Circuits (IDCs) All zones accept conventional detectors and any normally open contact device Four Class B Notification Appliance Circuits (NACs) One Form-A Alarm Relay One Form-A Trouble Relay One Form-A Supervisory Relay 3.0 amps of system power Max 30 conventional detectors in one zone. Auto/Manual mode setting enable walk test. Each Zone can be disabled, Sound output can be disabled. Manual active sound output enabled. Able to report short and broken circuit of detection zones. Designed with standby batteries and space provision for two sealed lead-acid batteries. Testing and disable functions. Can connect max 32 repeater panels by RS485 communication port Dimensions : 14.57" (37 cm) long X 17.32" (44 cm) high X 3.94"(10cm). Weight: 6.6kg (without battery) C Power 90-270 VAC, 50 Hz, 2.3 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation Battery (lead acid only) Maximum Charging Circuit: Normal Flat Charge—2*amp Maximum Charger Capacity: 18 Amp Hour batter Sound Output Device Circuits General Alarm Zones 1 through 16 Operation: All zones Class B Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum) Alarm Current: 15 mA threshold Short Circuit Current: 42 mA maximum Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.7K, ½ watt Detector Loop Current is suffici....

    Avoid fraud by meeting all sellers in-person to pay for items. BestB2B.COM does not offer any transaction or payment services.

PC | Touch

About | Contact | BBS | @2024 bestb2b.com

©BestB2B